Products

Etanorm

Design: Horizontal, long-coupled, single-stage volute casing pump with ratings and main dimensions to EN 733 in back pull-out design, with replaceable shaft sleeves / shaft protecting sleeves and casing wear rings. Design to ATEX.

Application: Spray irrigation, irrigation, drainage, district heating, water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, fire-fighting systems, handling of hot water, cooling water, fire-fighting water, oil, brine, drinking water, brackish water, service water, etc.

Etanorm SYT

Design: Horizontal, long-coupled volute casing pump in back pull-out design with ratings and main dimensions to EN 733, single-stage, with replaceable casing wear rings. Design to ATEX.

Application: Heat transfer systems (DIN 4754, VDI 3033) or hot water recirculation (DIN 4752).

Etabloc

Design: Close-coupled, single-stage volute casing pump, ratings to EN 733, with replaceable shaft sleeve and casing wear rings. Design to ATEX.

Application: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, condensate transport, swimming pools, handling of hot water, cooling water, fire-fighting water, seawater, oil, brine, drinking water, cleaning agents, brackish water, service water, etc.

Etachrom BC

Design: Close-coupled, horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings. Design to ATEX.

Application: Spray irrigation, irrigation, drainage and water supply systems, heating and air-conditioning systems, fire-fighting systems, swimming pools, handling of condensate, hot water, cooling water, fire-fighting water, oil, drinking water, cleaning agents, service water.

Etachrom NC

Design: Horizontal, single-stage annular casing pump, with ratings and main dimensions to EN 733, with replaceable casing wear rings. Design to ATEX.

Application: Water supply, spray irrigation, irrigation and drainage systems, heating and air-conditioning systems, handling of drinking water, service water, hot water, cooling water, swimming pool water, fire-fighting water, condensate, oil and cleaning agents.

Ama-Drainer N

Design: Fully floodable, vertical, close-coupled single-stage submersible motor pumps, IP 68, with or without level control, for a maximum immersion depth of 10 m.

Application: Automatic drainage of sumps, pits, yards and basements subject to a flooding risk, lowering of surface water levels, drainage of underground passages, water extraction from rivers and reservoirs.

Amarex KRT

Design: Vertical, single-stage submersible motor pump in close-coupled design, various impeller types, for wet or dry installation, stationary and transportable version. Design to ATEX.

Application: Handling of all types of abrasive or aggressive waste water in water and waste water engineering as well as industry, especially untreated sewage containing long fibres and solid substances, fluids containing gas / air, as well as raw, activated and digested sludge; sea water desalination.

Amarex N

Design: Vertical, single-stage submersible motor pump, for wet installation, stationary and transportable design. Amarex N pumps are floodable, single-stage, single-entry close-coupled pump sets which are not self-priming. Explosion-proof design available (ATEX, FM, CSA).

Application: Handling of all types of waste water, especially untreated sewage containing long fibres and solid substances, fluids containing gas/air, as well as raw, activated and digested sludge; Removing waste water from flooded rooms or surfaces.

KWP

Design: Horizontal, radially split volute casing pump in back pull-out-design, single-stage, single-entry, available with various impeller types: non-clogging impeller, open multi-vane impeller, free-flow impeller. Design to ATEX.

Application: Handling of pre-treated sewage, waste water, all types of slurries without stringy substances and pulps up to 5 % bone dry with a maximum density of 1.4 kg/dm3.

Movitec

Design: Multistage, vertical, high-pressure centrifugal pump in ring-section design with suction and discharge nozzles of identical nominal diameters arranged opposite to each other (in-line design), close-coupled. ATEX-compliant version available.

Application: Spray irrigation, irrigation, washing, water treatment, fire-fighting and pressure booster systems, hot water and cooling water recirculation, boiler feed systems etc.
Sizes
2, 4, 6, 10, 15, 25, 40, 60, 90

Multitec

Design: Multistage horizontal or vertical centrifugal pump in ring-section design, long-coupled, with axial or radial suction nozzle, cast radial impellers. Design to ATEX.

Application: Water and drinking water supply systems, general industry, pressure boosting systems, irrigation systems, in power stations, heating, filter, fire-fighting, reverse osmosis and washing plants, snow guns, etc.

Sewatec

Design: Horizontal or vertical volute casing pump with free-flow (F), single vane (E), multi-vane (K) and diagonal single vane (D) impellers, discharge flange to DIN and ANSI standards. Design to ATEX.

Application: Handling of sewage and all types of waste water in waste water management and industry.

Etaseco

Design: Horizontal / vertical, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, singlestage, single-entry, pump casing connecting dimensions to EN 733.

Application: Handling of aggressive, flammable, toxic, volatile, or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.

CPKN

Design: Horizontal, radially split volute casing pump in back pull-out design to EN 22 858 / ISO 2858 / ISO 5199, single-stage, single-entry, with radial impeller. Also available as variant with “wet” shaft, conical seal chamber, heatable volute casing (CPKNO-CHs) and/or semi-open impeller (CPKNO). Design to ATEX.

Application: Handling of aggressive liquids in the chemical and petrochemical industries as well as in refinery and fire-fighting systems, handling of brine.

Secochem Ex

Design: Horizontal, seal-less volute casing pump in back pull-out design with fully enclosed canned motor, low noise emission, with radial impeller, single-stage, single -entry, casing connecting dimensions to EN 22 858 / ISO 2858. Design to ATEX.

Application: Handling of aggressive, flammable, explosive, toxic, volatile or valuable liquids in the chemical and petrochemical industry, in environmental engineering and the general industry.